Power (kVA) | 82.5 kVA |
Genset Brand | Greaves Power |
Model Number | GPWII-PII-82.5 |
Phase | 3 Phase |
Fuel Consumption (at 100% Load) | 19.1 ltr/hr |
Fuel Tank Capacity | 150 Litres |
Dry Weight (Kg) | 1270 |
Frequency | 50 Hz |
Compression Ratio | 16.8 |
Dimension | 2880 x 1150 x 1540 mm |
Displacement | 3.66 L |
Maximum Allowable Back Pressure | 4 kPa |
Voltage | 220-400 V |
Product Details:
Brand | Greaves Power |
Compression Ratio | 16.8 |
Dimension (mm) | 2880 x 1150 x 1540 |
Displacement | 3.66 L |
Engine Model | 3GIITAG26 |
Engine Type | TCAC |
Genset Model | GPWII-PII-82.5 |
Maximum Allowable Back Pressure | 4 kPa |
Power | 82.5 KVA |
Weight (kg) | 1670 |
Genset Rating | Prime Power |
Genset Output KVA per KW | 82.5 / 66 |
Engine Rating or Max Power at Rated RPM in KW or BHP | 74.5 (101.2) |
No of Cylinders | 3 |
Cylinder Arrangement | Inline |
Bore x Stroke | 108 x 133 mm |
Governor Type | Mechanical |
Class of Governing | G2 |
Over Speed Trip | 1650 RPM |
Rated RPM | 1500 |
Engine with direct injection, water-cooled engine, 4 cylinders, in-line, 4 stroke rated at 1500 RPM, conforming to ISO 3046 / BS 5514 has the following specifications
Alternator-Crompton Greaves(optional-Stamford/equivalent)
Acoustic enclosure-Engine alternator assembly mounted on AVM with Silencer and S.S exhaust bellow suitably optimized to meet stringent sound emission standards as laid down by MOEF / CPCB
Control panel-RAL 9003 White Powder coated control panel manufactured with CRCA sheet provides
Power cables-Uninyvin copper conductor cables between Alternator & Control panel inside the canopy.
Literature:
Power (kVA)500 kVAGenset BrandGreaves PowerModel NumberGPWII-500Phase3 PhaseFuel Consumption (at 100% Load)107.9 Ltr/hrF... Continue
Power (kVA)400 kVAGenset BrandGreaves PowerModel NumberGPWII-400Phase3 PhaseFuel Consumption (at 100% Load)88.8 ltr/hrFu... Continue
Power (kVA)40 kVAGenset BrandGreaves PowerModel NumberGPWII-40APhase3 PhaseFuel Consumption (at 100% Load)9 Ltr/hrFuel T... Continue
Power (kVA)180 kVAGenset BrandGreaves PowerModel NumberGPWII-PII-180Phase3 PhaseFu... Continue
Power (kVA)25 kVAGenset BrandGreaves PowerModel NumberGPWII-PII-25EPhase3 PhaseFuel Consumption (at 100% Load)6.3 Ltr/hr... Continue
Power (kVA)10 kVAGenset BrandGreaves PowerModel NumberGPWII-PII-10EEngine MakeCummins... Continue
Power (kVA)125 kVAGenset BrandGreaves PowerModel NumberGPWII-PII-125Phase3 PhaseFuel Consumption (at 100% Load)28.6 ltr/... Continue
Power (kVA)350 kVAGenset BrandGreaves PowerModel NumberGPWII-320Phase3 PhaseFuel C... Continue
Power (kVA)20 kVAGenset BrandGreaves PowerModel NumberGPWII-PII-20XPhase3 PhaseFuel Consumption (at 100% Load)5 Ltr/hrFu... Continue
Power (kVA)30 kVAGenset BrandGreaves PowerModel NumberGPWII-PII-30XPhase3 PhaseFuel Consumption (at 100% Load)7.40 Ltr/h... Continue
PhaseThree PhaseFuel Tank Capacity25 ltrPower7.5 kVAVoltage220-380 VSpeed1500 rp... Continue
Power (kVA)62.5 kVAGenset BrandGreaves PowerModel NumberGPWII-PII-62.5Phase3 PhaseFuel Consumption (at 100% Load)14.9 lt... Continue
Power (kVA)160 kVAGenset BrandGreaves PowerModel NumberGPWII-PII-160Phase3 PhaseFuel Consumption (at 100% Load)36.5 ltr/... Continue
PhaseThree PhaseFuel Tank Capacity122 ltrPower2750 kVASpeed1500-1800 rpmVoltage2... Continue
Power (kVA)5 kVABrandGreaves PowerModel NumberGPA II - 5PhaseSingle PhaseFuel Consumption (at 100% Load)2 ltr/hrDry Weig... Continue
Fuel Tank Capacity100 ltrPhaseThree PhasePower35 kVASpeed1500 rpmVoltage220-440 ... Continue
Power (kVA)7.5 kVAGenset BrandGreaves PowerModel NumberGPW II - 7.5Phase3 PhaseFuel Consumption (at 100% Load)2.6 ltr/hr... Continue
PhaseThree PhasePower7.5 kVAVoltage415 VApplicationIndustrialFuel TypeDieselProtectionIP 54Complete Range of Diesel/Gas ... Continue
Compression Ratio16.8Dimension3000 x 1350 x 1884 mmDisplacement4.87 LMaximum Allowable Back Pressure4.5 kPaWeight1860 kg... Continue
Genset RatingPrime PowerBrandGreaves PowerFuel Tank Capacity100 LPhaseThree PhasePower45A kVABattery Capacity88 AHCompre... Continue
Genset RatingPrime PowerBrandGreaves PowerFuel TypeDieselBore & Stroke (mm)85 x 90Governor TypeMechanicalMaximum Allowab... Continue
Power (kVA)15 kVAGenset BrandGreaves PowerModel NumberGPWII-PII-15XPhase3 PhaseFuel Consumption (at 100% Load)3.9 Ltr/hr... Continue
Power (kVA)50 kVAGenset BrandGreaves PowerModel NumberGPWII-PII-50Phase3 PhaseFuel Consumption (at 100% Load)12.06 ltr/h... Continue
Power (kVA)75 kVAGenset BrandGreaves PowerModel NumberGPWII-PII-75Phase3 PhaseFuel Consumption (at 100% Load)17.57 Ltr/h... Continue
Genset RatingPrime PowerBrandGreaves PowerModelG-15-IIPhaseThree PhaseOutput Volta... Continue
Power (kVA)200 kVAGenset BrandGreaves PowerPhase3 PhaseFuel Consumption (at 100% Load)23.6 ltr/hrFuel Tank Capacity350 L... Continue
Power (kVA)250 kVAGenset BrandGreaves PowerModel NumberGPWII-PII-250Phase3 PhaseFuel Consumption (at 100% Load)58.2 Ltr/... Continue
PhaseThree PhaseBrandEicherFuel Tank Capacity100 ltrFrequency50 HzWeight3300 kg... Continue
Power (kVA)30 kVAGenset BrandGreaves PowerModel NumberGPWII-PII-30XPhase3 PhaseFuel Consumption (at 100% Load)7.40 Ltr/h... Continue
Power (kVA)125 kVAGenset BrandGreaves PowerPhase3 PhaseFuel Consumption (at 100% Load)28.6 ltr/hrFuel Tank Capacity350 L... Continue
Power (kVA)45 kVAGenset BrandGreaves PowerModel NumberGPWII-PII-45Phase3 PhaseFuel... Continue